{"product_id":"desktop-bera-epic-plus-pro","title":"Desktop Bera Epic Plus Pro","description":"\u003cdiv style=\"font-family: Arial, Helvetica, sans-serif; color: #222222; line-height: 1.65; font-size: 15px;\"\u003e\n\u003ch2 style=\"color: #006093; margin: 0 0 12px;\"\u003e\u003cbr\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eDesktop Bera Epic Plus Pro\u003c\/strong\u003e is a professional clinical auditory evoked potential system designed for hospitals, ENT departments, audiology centres, neuro-audiology clinics, diagnostic hearing centres, and advanced hearing assessment facilities. It supports \u003cstrong\u003eABR, MLR, and LLR\u003c\/strong\u003e testing as standard, with multiple upgradable test options for advanced clinical audiology and electrophysiology workflows.\u003c\/p\u003e\n\u003cp\u003eThis desktop BERA system is designed for \u003cstrong style=\"color: #fc6c15;\"\u003eclinical hearing assessment, neurological auditory pathway evaluation, newborn and pediatric hearing support workflow, and advanced diagnostic audiology\u003c\/strong\u003e. It offers single and dual channel operation, multiple stimulus options, user-defined test protocols, artifact rejection control, auto peak marking, waveform comparison, and latency-intensity graph support.\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eDesktop Bera Epic Plus Pro\u003c\/strong\u003e is compact, battery operated, and designed with a unique amplifier box that helps reduce susceptibility to external ambient noise and disturbances. It is suitable for clinical professionals who need reliable AEP testing with flexible protocol configuration, comprehensive database support, and upgrade options such as ASSR, VEMP, ECochG, P300, and BC-ABR depending on selected version.\u003c\/p\u003e\n\u003ch3 style=\"color: #006093; margin-top: 24px;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"padding-left: 20px; margin-top: 8px;\"\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #fc6c15;\"\u003eClinical AEP System:\u003c\/strong\u003e Supports ABR, MLR, and LLR testing for professional auditory evoked potential assessment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #fc6c15;\"\u003eSingle \u0026amp; Dual Channel Operation:\u003c\/strong\u003e Supports flexible testing workflow based on patient need and clinical protocol.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #fc6c15;\"\u003eMultiple Stimulus Options:\u003c\/strong\u003e Supports click, tone burst, and chirp stimulus types for different test requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #fc6c15;\"\u003eOptional Upgradable Tests:\u003c\/strong\u003e ASSR, VEMP, ECochG, P300, and BC-ABR options are available depending on selected version.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #fc6c15;\"\u003eUser-Defined Protocols:\u003c\/strong\u003e Allows custom test protocols for sleep and awake testing conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #fc6c15;\"\u003eAuto ABR Peak Marking:\u003c\/strong\u003e Supports automatic peak marking with manual override for correction where needed.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #fc6c15;\"\u003eWaveform Management:\u003c\/strong\u003e Allows comparison, merging, inversion, cross-correlation, add\/subtract functions, and waveform superimposition.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #fc6c15;\"\u003eCompact Desktop Design:\u003c\/strong\u003e Lightweight 1.95 kg unit with dimensions of 32 x 23 x 6 cm for clinical desktop setup.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #006093; margin-top: 24px;\"\u003eAvailable Versions\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 10px; font-size: 15px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eVersion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eVersion 1\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003ePlain - ABR, MLR and LLR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eVersion 2\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003ePlain with ASSR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eVersion 3\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003ePlain with C-VEMP and O-VEMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eVersion 4\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003ePlain with ECochG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eVersion 5\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003ePlain with BC-ABR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eVersion 6\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003ePlain with ASSR, C-VEMP, O-VEMP, ECochG and BC-ABR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"color: #006093; margin-top: 24px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 10px; font-size: 15px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eDesktop Bera Epic Plus Pro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eProduct Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eClinical BERA \/ AEP \/ ABR Testing System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eDesktop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eUsage\/Application\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eHospital, ENT Department, Audiology Centre, Clinical Diagnostic Setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eType of Audiometer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eClinical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eStandard Tests\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eABR, MLR, LLR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eOptional Tests\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eECochG, VEMP cVEMP \u0026amp; oVEMP, ASSR, P300, BC-ABR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eOperation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eSingle and Dual Channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eInput Stimulus Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eClick, Tone Burst and Chirp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eStimulus Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eUp to 130 dB SPL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eStimulus Polarity \/ Phase\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003ePositive, Negative, Alternating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eClick Polarity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eRarefaction, Condensation, Alternating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eOutput\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eAC R, AC L, AC Binaural, BC R, BC L and BC Forehead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eHP Filter Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e0 to 200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eLP Filter Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e100 to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eA\/D Converter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e16-bit, optically isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eStimulus Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e1 to 91.1 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eArtifact Rejection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eUser Defined Level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eSweeps\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eUser Selectable, 500 to 5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eCMRR\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e\u0026gt;110 dB @ 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eSmoothing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eOff to 8 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eAmplifier Gain\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eProgrammable, 1 to 150000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eAnalysis Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e1 to 1000 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eTrigger In \/ Trigger Out\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eTTL Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eImpedance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eBuilt-in meter for each channel, monitoring single electrode Z+ and Z- and differential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eMasking\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eWhite noise adjustable up to 125 dB SPL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eTotal Harmonic Distortion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e\u0026lt;1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eStimulus Envelopes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eRectangular, Blackmann, Hann, Barrlett, Gaussian\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eInternal Power Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e12V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e32 x 23 x 6 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e1.95 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e5°C to 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eOperating Relative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e10-90%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e-20°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"color: #006093; margin-top: 24px;\"\u003eProduct Benefits\u003c\/h3\u003e\n\u003cul style=\"padding-left: 20px; margin-top: 8px;\"\u003e\n\u003cli\u003eSupports advanced clinical auditory evoked potential testing in hospitals and audiology centres.\u003c\/li\u003e\n\u003cli\u003eDual channel operation helps improve testing workflow and waveform comparison efficiency.\u003c\/li\u003e\n\u003cli\u003eUpgradeable test options allow facilities to expand capabilities based on clinical demand.\u003c\/li\u003e\n\u003cli\u003eAuto ABR peak marking supports faster workflow while allowing manual correction where needed.\u003c\/li\u003e\n\u003cli\u003eBattery operation helps reduce AC mains-related signal disturbances and supports better patient safety.\u003c\/li\u003e\n\u003cli\u003eUnique amplifier box supports cleaner signal acquisition with reduced external noise interference.\u003c\/li\u003e\n\u003cli\u003eUser-defined protocols support customized sleep and awake testing workflows.\u003c\/li\u003e\n\u003cli\u003eComprehensive database tools help organize results by age, date, testing phase and other parameters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #006093; margin-top: 24px;\"\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eDesktop Bera Epic Plus Pro\u003c\/strong\u003e is suitable for ENT hospitals, audiology centres, diagnostic hearing clinics, neuro-audiology departments, pediatric hearing assessment setups, cochlear implant evaluation centres, occupational hearing assessment units, and clinical electrophysiology labs.\u003c\/p\u003e\n\u003cp\u003eIt can support ABR, MLR, LLR, P300, VEMP, ASSR, ECochG, and BC-ABR workflows depending on selected version and configuration. It is useful for newborn hearing evaluation support, difficult-to-test patient assessment, electrophysiological hearing threshold estimation, neurological auditory pathway review, and advanced clinical audiology testing.\u003c\/p\u003e\n\u003ch3 style=\"color: #006093; margin-top: 24px;\"\u003eHow to Use\u003c\/h3\u003e\n\u003col style=\"padding-left: 20px; margin-top: 8px;\"\u003e\n\u003cli\u003ePlace the Desktop Bera Epic Plus Pro on a stable clinical workstation and connect it to the required computer system.\u003c\/li\u003e\n\u003cli\u003ePrepare the patient according to test type, including skin preparation and electrode placement as per clinical protocol.\u003c\/li\u003e\n\u003cli\u003eCheck electrode impedance using the built-in impedance meter before starting the test.\u003c\/li\u003e\n\u003cli\u003eSelect the required test such as ABR, MLR, LLR, ASSR, VEMP, ECochG, P300 or BC-ABR based on selected version.\u003c\/li\u003e\n\u003cli\u003eChoose stimulus type, output, polarity, filter settings, sweeps, artifact rejection and analysis time according to protocol.\u003c\/li\u003e\n\u003cli\u003eStart recording and monitor waveform quality, noise level, patient movement and artifact rejection during acquisition.\u003c\/li\u003e\n\u003cli\u003eUse peak marking, waveform comparison, latency-intensity graph and report functions as required.\u003c\/li\u003e\n\u003cli\u003eSave, review, export or print test results according to clinic documentation workflow.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 style=\"color: #006093; margin-top: 24px;\"\u003eWhy Choose This BERA System?\u003c\/h3\u003e\n\u003cp\u003eThe Desktop Bera Epic Plus Pro is suitable for healthcare facilities that need a compact, clinical-grade AEP system with standard ABR, MLR and LLR testing plus flexible upgradable options. Its dual channel capability, programmable amplifier gain, broad stimulus support, artifact rejection, built-in impedance monitoring and waveform analysis tools make it practical for advanced audiology environments.\u003c\/p\u003e\n\u003cp\u003eFor ENT and audiology teams, this system supports comprehensive diagnostic workflow, clean signal acquisition, structured data management and flexible test configuration. Buyers should confirm selected version, required optional tests, computer compatibility, clinical protocol, installation support and training requirements before purchase.\u003c\/p\u003e\n\u003ch3 style=\"color: #006093; margin-top: 24px;\"\u003eFAQs\u003c\/h3\u003e\n\u003ch4 style=\"color: #fc6c15; margin-bottom: 6px;\"\u003e1. What is Desktop Bera Epic Plus Pro used for?\u003c\/h4\u003e\n\u003cp\u003eDesktop Bera Epic Plus Pro is used for clinical auditory evoked potential testing, including ABR, MLR and LLR. Depending on selected version, it can also support ASSR, VEMP, ECochG, P300 and BC-ABR testing in audiology and ENT departments.\u003c\/p\u003e\n\u003ch4 style=\"color: #fc6c15; margin-bottom: 6px;\"\u003e2. Which standard tests are included?\u003c\/h4\u003e\n\u003cp\u003eThe standard test configuration includes ABR, MLR and LLR. These tests support clinical auditory pathway and hearing assessment workflows. Additional tests are available depending on the selected version and upgrade configuration.\u003c\/p\u003e\n\u003ch4 style=\"color: #fc6c15; margin-bottom: 6px;\"\u003e3. Does this system support ASSR and VEMP?\u003c\/h4\u003e\n\u003cp\u003eYes, ASSR and VEMP are available in specific versions or optional configurations. The VEMP module supports cVEMP and oVEMP workflow, while ASSR supports frequency-specific threshold estimation and related clinical audiology applications.\u003c\/p\u003e\n\u003ch4 style=\"color: #fc6c15; margin-bottom: 6px;\"\u003e4. What stimulus types are supported?\u003c\/h4\u003e\n\u003cp\u003eThe system supports click, tone burst and chirp stimuli. Stimulus polarity options include positive, negative and alternating, while click options include rarefaction, condensation and alternating modes.\u003c\/p\u003e\n\u003ch4 style=\"color: #fc6c15; margin-bottom: 6px;\"\u003e5. Who should operate this BERA system?\u003c\/h4\u003e\n\u003cp\u003eThis system should be operated by trained audiologists, ENT professionals, neuro-audiology specialists, clinical technicians or authorized healthcare users. Proper patient preparation, electrode placement, protocol selection and waveform interpretation are essential for reliable results.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Medansh","offers":[{"title":"Plain (ABR MLR and LLR)","offer_id":46979946446932,"sku":"MSH1006910","price":592941.0,"currency_code":"INR","in_stock":true},{"title":"Plain with ASSR","offer_id":46979946479700,"sku":"MSH1006911","price":735000.0,"currency_code":"INR","in_stock":true},{"title":"Plain with C-VEMP and O-VEM","offer_id":46979946512468,"sku":"MSH1006912","price":685588.0,"currency_code":"INR","in_stock":true},{"title":"Plain with  ECochG","offer_id":46979946545236,"sku":"MSH1006913","price":685588.0,"currency_code":"INR","in_stock":true},{"title":"Plain with BC-ABR","offer_id":46979946578004,"sku":"MSH1006914","price":685588.0,"currency_code":"INR","in_stock":true},{"title":"Palin with ASSR C-VEMP O-VEM ECochG BC-ABR","offer_id":46979946610772,"sku":"MSH1006915","price":1012941.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/2520\/9684\/files\/desktop_bera_epic_plus_pro.webp?v=1780983997","url":"https:\/\/meddeygo.com\/products\/desktop-bera-epic-plus-pro","provider":"MeddeyGo.com","version":"1.0","type":"link"}