{"product_id":"vessel-electro-cautery-machine-vx-400","title":"Vessel Electro Cautery Machine VX-400","description":"\u003cdiv style=\"font-family: Arial, Helvetica, sans-serif; color: #222222; line-height: 1.65; font-size: 15px;\"\u003e\n\u003cp\u003eThe \u003cstrong\u003eVessel Electro Cautery Machine VX-400\u003c\/strong\u003e is a professional electrosurgical unit designed to support cutting, coagulation, bipolar output, and vessel sealing workflow in operation theatres and advanced surgical environments. It is suitable for hospitals, surgical centres, laparoscopic surgery setups, endoscopy departments, gynecology units, urology departments, oncology surgery areas, general surgery OTs, and other clinical procedure rooms where controlled high-frequency surgical energy is required.\u003c\/p\u003e\n\u003cp\u003eThis \u003cstrong style=\"color: #fc6c15;\"\u003eVX-400 vessel sealing electrosurgical unit\u003c\/strong\u003e supports multiple surgical output modes including monopolar cut, monopolar coagulation, bipolar operation, and vessel sealing mode. With a pure cutting output of up to \u003cstrong\u003e400 watts\u003c\/strong\u003e, advanced coagulation modes, bipolar cut support, and sealing pulse output options, the unit is designed for trained surgical professionals who need flexible energy control across open, endoscopic, laparoscopic, and minimally invasive procedures.\u003c\/p\u003e\n\u003cp\u003eThe VX-400 works with an output frequency of \u003cstrong\u003e400-550 kHz\u003c\/strong\u003e and includes vessel sealing mode with pure sine wave \u003cstrong\u003e440 kHz\u003c\/strong\u003e. It also supports PPQM system monitoring for patient return electrode safety. The machine should be operated only by trained surgeons, OT teams, biomedical technicians, and authorized healthcare professionals following electrosurgical safety protocol, patient plate monitoring guidelines, and compatible accessory instructions.\u003c\/p\u003e\n\u003ch3 style=\"color: #006093; margin-top: 24px;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul style=\"padding-left: 20px; margin-top: 8px;\"\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #fc6c15;\"\u003eAdvanced Vessel Sealing Support:\u003c\/strong\u003e Includes seal-pulse output modes for vessel sealing workflow when used with compatible sealing instruments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #fc6c15;\"\u003e400W Pure Cutting Output:\u003c\/strong\u003e Supports demanding surgical cutting applications in professional OT environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #fc6c15;\"\u003eMultiple Monopolar Cut Modes:\u003c\/strong\u003e Pure, Blend I, Blend II, Blend III, and Blend IV allow different cutting and coagulation effects.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #fc6c15;\"\u003eMonopolar Coagulation Modes:\u003c\/strong\u003e Soft, Dessicate, Force, and Spray modes support varied coagulation requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #fc6c15;\"\u003eBipolar Modes:\u003c\/strong\u003e Micro, Standard, and Macro\/Cut bipolar settings support controlled bipolar surgical workflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #fc6c15;\"\u003ePPQM System:\u003c\/strong\u003e Patient return electrode monitoring support helps improve safety during monopolar procedures.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #fc6c15;\"\u003eWide Surgical Application Range:\u003c\/strong\u003e Suitable for ophthalmic, laparoscopic, GI, ortho, gynecology, urology, ENT, spine, and general surgery workflows.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #fc6c15;\"\u003eCompact OT Design:\u003c\/strong\u003e 350 x 350 x 130 mm size and 6.5 kg net weight support practical placement in procedure rooms and OTs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #006093; margin-top: 24px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 10px; font-size: 15px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eProduct Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eVessel Electro Cautery Machine VX-400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eProduct Category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eVessel Sealing Electrosurgical Unit \/ Electro Cautery Machine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e190-260 Volt, 50Hz AC; optional 90-120 Volts, 60Hz AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eOutput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e400-550 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eVessel Sealing Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003ePure sine wave 440 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003ePPQM Measuring Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e85 kHz ± 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003ePPQM Measuring Current\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e\u0026lt; 10 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eDual Area Patient Return Electrode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e5-135Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eSingle Area Patient Return Electrode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e\u0026lt; 10Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e350 x 350 x 130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e6.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"color: #006093; margin-top: 24px;\"\u003eOutput Data\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 10px; font-size: 15px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eCategory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eMode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eMax P-P Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eRated Load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eMax Power\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eCrest Factor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eMonopolar Cut\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003ePure\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e900\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e500Ω\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e400W\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eMonopolar Cut\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eBlend I\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e1100\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e500Ω\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e300W\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e2.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eMonopolar Cut\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eBlend II\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e1200\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e500Ω\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e250W\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e2.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eMonopolar Cut\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eBlend III\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e1300\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e500Ω\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e200W\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e2.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eMonopolar Cut\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eBlend IV\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e1300\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e500Ω\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e150W\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e3.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eMonopolar Coag.\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eSoft\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e1600\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e500Ω\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e300W\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e3.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eMonopolar Coag.\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eDessicate\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e1800\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e500Ω\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e250W\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e3.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eMonopolar Coag.\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eForce\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e2100\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e500Ω\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e200W\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e4.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eMonopolar Coag.\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eSpray\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e3500\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e500Ω\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e120W\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e6.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eBipolar\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eMicro\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e320\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e100Ω\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e70W\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eBipolar\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eStandard\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e460\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e100Ω\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e90W\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eBipolar\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eMacro\/Cut\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e600\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e100Ω\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e120W\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"color: #006093; margin-top: 24px;\"\u003eVessel Sealing Output\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 10px; font-size: 15px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eSeal Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px; background: #f5f9fb;\"\u003e\u003cstrong\u003eOutput Detail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eSoft-Seal\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e120W at 100Ω, CF 1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eMed-Seal\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e200W at 100Ω, CF 1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003eRapid-Seal\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #d9d9d9; padding: 10px;\"\u003e350W at 100Ω, CF 1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"color: #006093; margin-top: 24px;\"\u003eProduct Benefits\u003c\/h3\u003e\n\u003cul style=\"padding-left: 20px; margin-top: 8px;\"\u003e\n\u003cli\u003eSupports advanced cutting, coagulation, bipolar, and vessel sealing workflow in OT environments.\u003c\/li\u003e\n\u003cli\u003eMultiple blend and coagulation modes help surgeons select output according to tissue requirement.\u003c\/li\u003e\n\u003cli\u003eVessel sealing output supports sealing workflow where compatible instruments and protocols are used.\u003c\/li\u003e\n\u003cli\u003ePPQM system supports patient return electrode monitoring during applicable procedures.\u003c\/li\u003e\n\u003cli\u003eCompact 6.5 kg design supports convenient placement on surgical trolleys or OT workstations.\u003c\/li\u003e\n\u003cli\u003eWide application support makes it suitable for open, laparoscopic, endoscopic, and minimally invasive surgery setups.\u003c\/li\u003e\n\u003cli\u003eDifferent bipolar outputs support micro, standard, and macro\/cut applications.\u003c\/li\u003e\n\u003cli\u003eInput voltage range supports practical use across different clinical electrical setups.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #006093; margin-top: 24px;\"\u003eApplications\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eVessel Electro Cautery Machine VX-400\u003c\/strong\u003e is suitable for ophthalmic surgery, laparo surgery, endoscopy, GI surgery, orthopedic surgery, open and general surgery, oncology surgery, gynecology, hernia procedures, GI endocut applications, papillotomy, polypectomy, underwater procedures, urology, gynecological TCRE, hysteroscopy, thoracotomy, plastic surgery, neuro surgery, ENT, spine, thoracic surgery, and cardiac surgery.\u003c\/p\u003e\n\u003cp\u003eIt is suitable for open, endoscopic, laparoscopic, and minimally invasive surgical workflows when used with compatible accessories and under trained surgical supervision. Final application depends on patient condition, surgical protocol, output mode, and compatible instrument selection.\u003c\/p\u003e\n\u003ch3 style=\"color: #006093; margin-top: 24px;\"\u003eHow to Use\u003c\/h3\u003e\n\u003col style=\"padding-left: 20px; margin-top: 8px;\"\u003e\n\u003cli\u003ePlace the VX-400 on a stable OT trolley or surgical workstation before use.\u003c\/li\u003e\n\u003cli\u003eConnect the unit to the correct operating voltage supply and inspect the device condition.\u003c\/li\u003e\n\u003cli\u003eAttach compatible patient return electrode, monopolar handpiece, bipolar instrument, or vessel sealing instrument as per procedure requirement.\u003c\/li\u003e\n\u003cli\u003eSelect the required mode such as pure cut, blend, soft coag, spray coag, bipolar, or vessel sealing mode.\u003c\/li\u003e\n\u003cli\u003eSet the output level according to surgical requirement, tissue response, and clinical protocol.\u003c\/li\u003e\n\u003cli\u003eConfirm patient plate monitoring, accessory connection, and safety indicators before activating output.\u003c\/li\u003e\n\u003cli\u003eMonitor tissue response, thermal spread, device status, and patient safety throughout the procedure.\u003c\/li\u003e\n\u003cli\u003eAfter use, switch off the unit, disconnect accessories safely, and clean external surfaces according to OT protocol.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3 style=\"color: #006093; margin-top: 24px;\"\u003eWhy Choose This Vessel Cautery Machine?\u003c\/h3\u003e\n\u003cp\u003eThe Vessel Electro Cautery Machine VX-400 is suitable for healthcare facilities that need a compact, advanced electrosurgical unit with high-power cutting, multiple coagulation modes, bipolar output, PPQM monitoring, and vessel sealing support. Its technical output range makes it useful for various surgical departments and procedure types.\u003c\/p\u003e\n\u003cp\u003eFor hospitals, surgical centres, and specialty OT teams, this unit supports flexible energy selection across open, laparoscopic, endoscopic, and minimally invasive procedures. Buyers should confirm accessory compatibility, vessel sealing instruments, patient return electrode requirements, service support, and user training before purchase.\u003c\/p\u003e\n\u003ch3 style=\"color: #006093; margin-top: 24px;\"\u003eFAQs\u003c\/h3\u003e\n\u003ch4 style=\"color: #fc6c15; margin-bottom: 6px;\"\u003e1. What is the Vessel Electro Cautery Machine VX-400 used for?\u003c\/h4\u003e\n\u003cp\u003eThe VX-400 is used for surgical cutting, coagulation, bipolar output, and vessel sealing workflow. It supports open, laparoscopic, endoscopic, and minimally invasive surgery applications when used by trained surgical professionals with compatible accessories.\u003c\/p\u003e\n\u003ch4 style=\"color: #fc6c15; margin-bottom: 6px;\"\u003e2. What is the maximum cutting output?\u003c\/h4\u003e\n\u003cp\u003eThe pure monopolar cutting mode provides up to 400W maximum power at 500Ω rated load. Other blend and coagulation modes have different output values based on mode and clinical requirement.\u003c\/p\u003e\n\u003ch4 style=\"color: #fc6c15; margin-bottom: 6px;\"\u003e3. Does this unit support vessel sealing?\u003c\/h4\u003e\n\u003cp\u003eYes, the unit includes vessel sealing mode with pure sine wave 440 kHz and seal-pulse output options. Soft-Seal, Med-Seal, and Rapid-Seal outputs are provided as per technical data.\u003c\/p\u003e\n\u003ch4 style=\"color: #fc6c15; margin-bottom: 6px;\"\u003e4. What is the PPQM system?\u003c\/h4\u003e\n\u003cp\u003eThe PPQM system supports patient return electrode monitoring. It includes measuring frequency of 85 kHz ± 10 kHz, measuring current below 10 µA, and return electrode impedance monitoring as per supplied technical details.\u003c\/p\u003e\n\u003ch4 style=\"color: #fc6c15; margin-bottom: 6px;\"\u003e5. Who should operate this machine?\u003c\/h4\u003e\n\u003cp\u003eThis machine should be operated by trained surgeons, OT teams, biomedical technicians, or authorized healthcare professionals. Correct accessory setup, patient return electrode placement, output selection, and safety monitoring are essential.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Medansh","offers":[{"title":"Default Title","offer_id":47091548913748,"sku":"MSH1006898","price":140000.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0629\/2520\/9684\/files\/vessel_electro_cautery.webp?v=1781610060","url":"https:\/\/meddeygo.com\/products\/vessel-electro-cautery-machine-vx-400","provider":"MeddeyGo.com","version":"1.0","type":"link"}