Skin Grafting Blade Carbon Steel Sterile
Skin Grafting Blade Carbon Steel Sterile
In stock
- Free shipping over ₹500
- 7 Day Returns
Couldn't load pickup availability
Share this product
The Skin Grafting Blade Carbon Steel Sterile is a high-precision surgical blade specifically engineered for harvesting skin grafts in reconstructive, burn, and plastic surgery procedures. In modern surgical environments, accuracy, sterility, and blade consistency are critical for optimal graft outcomes. Therefore, surgeons require a skin grafting blade that ensures clean incisions, uniform thickness control, and dependable cutting performance.
Because graft survival depends heavily on harvesting precision, instrument quality plays a direct role in patient recovery. Consequently, this sterile, single-use skin grafting blade delivers controlled slicing performance while minimizing trauma to adjacent tissues. Moreover, its refined construction supports predictable graft extraction across different surgical cases.
Product Overview
A skin grafting blade is a specialized surgical instrument used to harvest split-thickness and full-thickness grafts from donor sites. Unlike conventional surgical blades, this blade features a straight design combined with an angled cutting edge. As a result, surgeons can perform smooth and controlled to-and-fro motions required for accurate graft harvesting.
Furthermore, the blade is manufactured from high-grade carbon steel, which ensures exceptional sharpness and durability. Therefore, surgeons experience consistent cutting efficiency throughout the procedure. In addition, the sterile packaging supports strict infection control compliance in operating rooms and trauma centers.
This blade is compatible with multiple grafting systems, including standard humby knife instruments. Consequently, it integrates seamlessly into existing surgical setups without requiring equipment modification.
Key Features
- Sterile & Single-Use: Each skin grafting blade is individually packed and sterilized. Therefore, cross-contamination risks are significantly reduced.
- Universal Compatibility: Designed to fit standard grafting handles, including humby knife systems. As a result, surgeons maintain flexibility in instrument selection.
- Angled Cutting Edge: Engineered for controlled slicing motion. Consequently, graft surfaces remain clean and uniform.
- Straight Blade Profile: Facilitates steady, balanced sawing motion required for uniform graft thickness.
- Carbon Steel Construction: Offers superior sharpness, precision, and fine-edge retention during delicate surgical procedures.
Technical Specifications
| Product Name | Skin Grafting Blade |
| Blade Number | No. 22 |
| Material | Carbon Steel |
| Shape | Straight Blade |
| Cutting Edge | Angled |
| Dimensions | 157 x 18 x 0.229 mm |
| Sterility | Yes – Individually Packed |
| Usage | Single-Use |
Available Variants
To meet different hospital procurement requirements, the skin grafting blade is available in multiple pack sizes. Therefore, healthcare facilities can select quantities based on surgical volume and inventory planning.
- Pack of 4: Ideal for clinics, small surgical centers, or emergency stock requirements.
- Pack of 12: Suitable for moderate-volume outpatient surgical departments.
- Pack of 24: Recommended for hospitals performing regular reconstructive and burn procedures.
- Pack of 48: Best suited for high-volume trauma centers and large surgical facilities.
Because bulk variants reduce ordering frequency, they support cost-efficient inventory management. Additionally, larger packs ensure uninterrupted surgical workflow.
Clinical Applications
The skin grafting blade is widely used in reconstructive and burn surgery. Because graft thickness directly influences engraftment success, surgeons prioritize sharp and stable blades. Therefore, this blade supports consistent harvesting results even in high-demand surgical environments.
In burn care management, harvested grafts cover raw wound beds to promote vascularized healing. Consequently, infection risk decreases while tissue regeneration accelerates. Additionally, plastic surgeons use this blade in cosmetic reconstruction procedures where uniform graft quality is essential.
- Split-thickness skin graft harvesting
- Full-thickness graft extraction
- Burn wound coverage procedures
- Plastic and reconstructive surgery
- Trauma-related tissue restoration
Procedure Overview
To begin, the donor site is prepared and disinfected according to surgical protocol. Next, the limb or donor area is stabilized to ensure precision.
After preparation, the skin grafting blade is securely attached to a compatible handle such as a humby knife. Then, the surgeon applies steady and controlled pressure.
Subsequently, a consistent to-and-fro motion extracts the graft at the desired thickness. Meanwhile, depth adjustment allows surgeons to regulate graft characteristics according to clinical needs.
Thin grafts appear translucent, whereas full-thickness grafts display a white appearance with visible subcutaneous tissue. Therefore, blade sharpness and control remain crucial throughout the harvesting process.
Compatibility & Interchangeability
This blade is fully compatible with standard humby knife systems. Therefore, surgeons seeking reliable humby knife blade replacements can integrate this model effortlessly.
Additionally, professionals comparing alternatives such as skin grafting blade b braun options will find similar dimensional compatibility and cutting efficiency. Consequently, operating room teams maintain workflow continuity.
Benefits for Surgeons & Hospitals
The carbon steel cutting edge ensures smooth slicing without irregular resistance. As a result, graft margins remain clean and consistent.
Because the angled edge allows controlled depth, surrounding tissue experiences minimal disruption. Therefore, post-operative healing outcomes improve.
Individually packed sterile blades eliminate contamination concerns. Consequently, surgical teams maintain strict infection control compliance.
Since the blade fits humby knife instruments directly, preparation time decreases. Moreover, single-use design eliminates re-sterilization delays.
Infection Control & Safety Standards
In surgical environments, sterility is non-negotiable. Therefore, each skin grafting blade undergoes individual sterile packaging before distribution.
Additionally, the single-use format eliminates risks associated with reprocessing errors. Consequently, patient safety and procedural reliability remain uncompromised.
Why Choose MeddeyGo
MeddeyGo supplies certified surgical instruments and consumables to hospitals, trauma centers, and reconstructive surgery departments across India. Because surgical outcomes depend on instrument reliability, MeddeyGo partners with trusted manufacturers to ensure consistent quality.
Furthermore, prepaid and partial COD options provide procurement flexibility. Additionally, nationwide distribution ensures timely product availability. Consequently, healthcare institutions receive dependable supply support whenever required.
- Certified surgical consumables
- Trusted supplier for plastic and reconstructive surgery
- Reliable nationwide delivery
- Professional healthcare support
