Boyle’s Apparatus Anaesthesia Machine SS with 4 Cylinders
Boyle’s Apparatus Anaesthesia Machine SS with 4 Cylinders
In stock
- Free shipping over ₹500
- 7 Day Returns
Couldn't load pickup availability
Share this product
The Boyle's Apparatus Anaesthesia Machine in stainless steel is a professional continuous flow anaesthesia workstation. Anaesthetists and operation theatre teams use it to deliver a controlled and precise mixture of anaesthetic gases and oxygen to patients during surgical procedures. Because it supports 4 gas cylinders, it accommodates the gas configurations required for general anaesthesia in hospital operation theatres.
Moreover, the stainless steel construction provides durability and ease of surface disinfection in surgical environments. As a result, the machine maintains hygiene standards required for operation theatre use. Therefore, it forms a reliable and clinically appropriate anaesthesia apparatus for hospitals, surgical centres, and operation theatre setups.
This anaesthesia workstation is suitable for the following clinical settings:
- General surgery operation theatres in hospitals and nursing homes
- Orthopaedic, gynaecology, and ENT surgical suites
- Day surgery centres and multi-speciality hospitals
- Teaching hospitals and medical college operation theatres
What Is a Boyle's Apparatus Anaesthesia Machine
A Boyle's apparatus is a type of continuous flow anaesthesia machine. It delivers a controlled and metered flow of medical gases — typically oxygen, nitrous oxide, and an inhalational anaesthetic agent — to the patient via a breathing circuit. Because gas flow rates are set precisely using calibrated flowmeters, the anaesthetist maintains exact control of the gas mixture throughout the procedure. Therefore, the Boyle's apparatus remains a standard anaesthesia workstation in Indian hospitals and operation theatres.
Furthermore, the Boyle's apparatus design supports the safe administration of inhalational anaesthesia. Because it integrates the gas supply system, flowmeters, vaporiser mount, and breathing circuit into a single mobile workstation, the anaesthetist manages all components from one location. As a result, this anaesthesia apparatus improves procedural organisation, reduces setup time, and supports safe anaesthesia delivery in clinical environments of varying complexity.
Key Features
Stainless Steel Construction
The machine uses stainless steel for the main frame and working surfaces. Stainless steel resists corrosion and withstands repeated surface disinfection with hospital-grade cleaning agents. Because operation theatre equipment requires rigorous infection control standards, the stainless steel build directly supports OT hygiene compliance. Furthermore, it provides structural durability for long-term use in demanding surgical environments.
Four-Cylinder Gas Supply Configuration
The apparatus supports four gas cylinders simultaneously. This configuration accommodates oxygen, nitrous oxide, and additional medical gas cylinders as required for different anaesthesia protocols. Because having multiple cylinders connected reduces the risk of gas interruption during a procedure, the 4-cylinder design improves safety and operational reliability. As a result, anaesthetists manage gas supply without interrupting the procedure.
Flowmeters and Gas Delivery System
Calibrated flowmeters allow precise measurement and control of each gas flow rate during anaesthesia administration. Because accurate gas flow directly affects the depth and safety of anaesthesia, calibrated flowmeters are a critical component of any anaesthesia workstation. Therefore, the Boyle's apparatus delivers the controlled gas mixture that safe inhalational anaesthesia requires throughout each procedure.
Breathing Circuit and Vaporiser Mount
The apparatus includes a breathing circuit for patient gas delivery and a vaporiser mount for inhalational anaesthetic agents. Because the breathing circuit connects the gas delivery system directly to the patient's airway, it forms an essential part of the complete anaesthesia apparatus setup. Furthermore, the vaporiser mount supports attachment of standard vaporiser units, which consequently allows the machine to deliver volatile anaesthetic agents as part of a complete anaesthesia protocol.
Mobile Trolley Base with Castors
The machine mounts on a mobile trolley base with lockable castors. Because operation theatre layouts vary and equipment often needs repositioning between procedures, the mobile base improves workflow flexibility. As a result, the anaesthesia apparatus moves easily within the OT and locks securely in position during surgery. Therefore, the design supports both procedural safety and OT operational efficiency.
Technical Specifications
| Specification | Details |
|---|---|
| Product Name | Boyle's Apparatus Anaesthesia Machine SS with 4 Cylinders |
| Construction | Stainless Steel (SS) Frame and Work Surface |
| Cylinder Configuration | 4 Cylinders (Oxygen, Nitrous Oxide and Medical Gases) |
| Height | 152 cm |
| Width | 65 cm |
| Depth | 60 cm |
| Mobility | Mobile Trolley Base with Lockable Castors |
| Gas Delivery | Calibrated Flowmeters for Precise Gas Flow Control |
| Breathing Circuit | Integrated Breathing Circuit for Patient Gas Delivery |
| Vaporiser | Vaporiser Mount for Inhalational Anaesthetic Agents |
| Ideal For | Hospitals, Operation Theatres, Surgical Centres, Medical Colleges |
Clinical Applications and Uses
The Boyle's apparatus anaesthesia machine suits all surgical settings that require general inhalational anaesthesia. Because it delivers a complete and controlled anaesthesia gas supply system in a single mobile unit, it meets the requirements of operation theatres across multiple surgical specialities.
General Surgery Operation Theatres
General surgery departments use the Boyle's apparatus as a standard anaesthesia workstation for routine elective and emergency surgical procedures. Because the 4-cylinder configuration handles the gas volumes required for extended procedures, it suits both short and long-duration surgeries. As a result, anaesthesia teams rely on it for consistent and safe gas delivery across a full surgical list.
Orthopaedic, Gynaecology and ENT Surgical Suites
Surgical specialities including orthopaedics, gynaecology, and ENT use the Boyle's apparatus for their respective procedure requirements. Because these specialities involve both short and extended surgical cases under general anaesthesia, the flexible gas delivery system and vaporiser mount accommodate a range of anaesthetic protocols. Furthermore, the mobile base allows easy positioning within speciality OT layouts.
Medical Colleges and Teaching Hospitals
In addition, medical college operation theatres and teaching hospitals use the Boyle's apparatus for both clinical procedures and anaesthesia training. Because anaesthesia residents and medical students must learn to set up and operate anaesthesia workstations as part of their clinical education, this apparatus provides the hands-on training platform they require. Consequently, it serves both an active clinical function and a teaching role in academic hospital settings.
Clinical Context and Professional Standards
The Boyle's apparatus is a long-established anaesthesia workstation design that remains in widespread use in Indian hospitals. Moreover, the Central Drugs Standard Control Organisation (CDSCO) and the Bureau of Indian Standards (BIS) regulate medical gas equipment and anaesthesia apparatus standards in India. Because anaesthesia machine safety directly affects patient outcomes during surgery, compliance with applicable equipment standards is a non-negotiable requirement for clinical use.
Furthermore, the Indian Society of Anaesthesiologists (ISA) provides professional guidelines on anaesthesia equipment standards, pre-use safety checks, and maintenance protocols for anaesthesia workstations. Because correct setup, calibration, and maintenance of the Boyle's apparatus directly affect patient safety, institutions must ensure that all anaesthesia machines undergo regular servicing. Therefore, procurement of anaesthesia apparatus should always include a maintenance and calibration plan.
Why Choose MeddeyGo
MeddeyGo is a trusted platform for professional operation theatre and anaesthesia equipment in India. Because we source products from verified manufacturers and authorised supply channels, we provide hospitals and surgical centres with reliable anaesthesia apparatus at competitive prices.
Clinically Suitable OT Equipment
Every product listed on MeddeyGo undergoes review for clinical and technical suitability. As a result, hospital procurement teams can be confident they purchase equipment appropriate for operation theatre use. Moreover, we provide full technical specifications and transparent product information to support informed procurement decisions.
Support for Hospital and Bulk Orders
MeddeyGo supports procurement for hospitals, surgical centres, nursing homes, and medical colleges. Therefore, we offer institutional pricing, documentation assistance, and dedicated account management for bulk buyers. Consequently, procurement teams complete their orders efficiently and with the paperwork required for hospital purchase processes.
Delivery and After-Sales Support
Our team dispatches orders with packaging appropriate for medical equipment. Furthermore, our after-sales team assists with delivery coordination, installation queries, and warranty matters. As a result, hospitals receive dependable support from purchase through to commissioning.
Frequently Asked Questions (FAQs)
About the Machine and Its Components
Why is stainless steel used for the anaesthesia machine frame?
What gases does this 4-cylinder Boyle's apparatus support?
About Setup, Dimensions and Use
Does this anaesthesia machine require professional installation?
Who should operate this Boyle's apparatus?