Electro Surgical Unit Analog Power 300W Eco ESU - 402A V2
Electro Surgical Unit Analog Power 300W Eco ESU - 402A V2
In stock
- Free shipping over ₹500
Couldn't load pickup availability
Share this product
The Electro Surgical Unit Analog Power 300W Eco ESU - 402A V2 is a professional electrosurgical unit designed to support surgical cutting and coagulation workflow in hospitals, operation theatres, surgical clinics, minor OT rooms, gynecology procedure areas, urology setups, ENT procedure rooms, and healthcare facilities requiring controlled electrosurgical output.
This 300W analog electrosurgical unit provides essential modes including Pure Cutting, Blend Cutting, Contact Coagulation, Bipolar Coagulation, and Bipolar Cutting. These modes support different clinical requirements where trained surgeons and OT teams need controlled high-frequency energy delivery for compatible procedures.
The unit features instant power setting by analog knob, allowing quick and practical power adjustment during procedure preparation. Its 300W maximum output makes it suitable for routine surgical applications where reliable cutting and coagulation support is required. The device should be operated only by trained healthcare professionals according to clinical protocol, user manual guidance, and electrosurgical safety precautions.
Key Features
- 300W Maximum Power: Supports routine electrosurgical cutting and coagulation applications in clinical settings.
- Analog Power Setting: Instant power adjustment through analog knob for straightforward operation.
- Pure Cutting Mode: Designed to support surgical cutting workflow where clinically appropriate.
- Blend Cutting Mode: Supports cutting with controlled coagulation effect for selected procedure needs.
- Contact Coagulation: Helps support coagulation workflow during compatible surgical procedures.
- Bipolar Coagulation: Supports controlled bipolar coagulation applications with compatible instruments.
- Bipolar Cutting: Provides bipolar cutting support for suitable clinical procedures and accessories.
- Compact OT Use: Suitable for hospitals, minor OTs, surgical centres, and clinical procedure rooms.
Technical Specifications
| Product Name | Electro Surgical Unit Analog Power 300W Eco ESU - 402A V2 |
| Product Category | Electrosurgical Unit / HF Surgical Cautery Machine |
| Maximum Power | 300 W |
| Frequency | 50 Hz |
| Voltage | 240 V |
| Power Setting | Instant power setting by analog knob |
| Cutting Modes | Pure Cutting, Blend Cutting, Bipolar Cutting |
| Coagulation Modes | Contact Coagulation, Bipolar Coagulation |
| Operation Type | Analog control operation |
| Suitable For | Hospitals, Operation Theatres, Surgical Clinics, Minor OT Rooms and Procedure Areas |
Product Benefits
- Supports essential surgical cutting and coagulation workflow in OT environments.
- Analog knob control allows quick power adjustment during procedure setup.
- 300W maximum output supports routine electrosurgical applications.
- Pure and blend cutting modes provide flexibility for different surgical needs.
- Contact coagulation mode supports coagulation workflow during compatible procedures.
- Bipolar coagulation and bipolar cutting support controlled bipolar applications.
- Suitable for hospitals, surgical centres, specialty clinics, and minor procedure rooms.
- Simple analog interface supports practical use by trained clinical professionals.
Applications
The Electro Surgical Unit Analog Power 300W Eco ESU - 402A V2 is suitable for general surgery, minor OT procedures, gynecology procedures, urology applications, ENT procedure support, bipolar surgical applications, and routine operation theatre use. It can be used in hospitals, procedure rooms, outpatient surgical units, and clinical departments requiring electrosurgical cutting and coagulation support.
Final usage depends on selected accessories, compatible electrodes, handpieces, bipolar instruments, patient safety setup, procedure type, and clinical judgement. The unit should always be used with proper safety checks and trained supervision.
How to Use
- Place the ESU unit on a stable OT trolley or procedure workstation before use.
- Connect the unit to a suitable 240 V, 50 Hz power supply.
- Inspect analog knobs, output ports, cables, accessories, and power condition before operation.
- Connect compatible electrodes, patient plate, handpiece, bipolar instrument, or foot switch as per procedure requirement.
- Select the required mode such as pure cutting, blend cutting, contact coagulation, bipolar coagulation, or bipolar cutting.
- Adjust power using the analog knob according to tissue requirement and surgeon preference.
- Monitor tissue response, patient safety, and machine operation throughout the procedure.
- After use, switch off the unit, disconnect accessories safely, and clean external surfaces as per OT protocol.
Why Choose This Analog ESU?
The ESU - 402A V2 is suitable for healthcare facilities that need a practical 300W analog electrosurgical unit with essential cutting, coagulation, and bipolar functions. Its simple analog power setting, compact operating style, and multi-mode support make it useful for routine surgical and minor OT procedures.
For hospitals, clinics, and surgical departments, this unit supports essential electrosurgical workflow in an economical and easy-to-operate format. Buyers should confirm compatible accessories, patient plate system, power supply, service support, and operator training before purchase.
FAQs
1. What is the Electro Surgical Unit Analog Power 300W Eco ESU - 402A V2 used for?
It is used for electrosurgical cutting and coagulation support in operation theatres, surgical clinics, minor procedure rooms, and healthcare procedure areas. It supports pure cutting, blend cutting, contact coagulation, bipolar coagulation, and bipolar cutting.
2. What is the maximum power output?
The maximum power output is 300 W as per the provided details. Power should be selected carefully by trained healthcare users according to procedure type, tissue response, and safety protocol.
3. How is power adjusted in this ESU?
Power is adjusted instantly using an analog knob. This allows trained users to select output levels quickly during procedure setup while following the operating instructions and clinical safety requirements.
4. Does this unit support bipolar operation?
Yes, this unit supports bipolar coagulation and bipolar cutting modes. These functions should be used only with compatible bipolar instruments, cables, and proper clinical setup.
5. Who should operate this electrosurgical unit?
This electrosurgical unit should be operated by trained surgeons, OT staff, biomedical technicians, or authorized healthcare professionals. Proper accessory connection, patient safety setup, output selection, and electrosurgical precautions are essential.
