i6 Defibrilator Monitor
i6 Defibrilator Monitor
In stock
- Free shipping over ₹500
- 7 Day Returns
Couldn't load pickup availability
Share this product
The i6 Defibrillator Monitor is a professional emergency cardiac care device designed to support defibrillation, patient monitoring, pacing, and AED operation in a single compact system. It is suitable for hospitals, emergency departments, ICUs, CCUs, operation theatres, ambulance services, emergency response teams, and critical care environments where rapid cardiac response and continuous monitoring are important.
This defibrillator monitor supports manual defibrillation, AED mode, pacing, and vital sign monitoring, helping clinical teams manage cardiac arrest, shockable rhythm situations, patient transport, and emergency monitoring workflows. The device uses a Biphasic Truncated Exponential waveform with impedance compensation and supports energy selection from 1J to 360J, allowing trained professionals to select appropriate therapy levels as per clinical protocol.
Built with a 7-inch color display, rapid charge performance, CPR guidance mode, ECG monitoring, SpO2, NIBP, respiration, and temperature monitoring support, this device is designed for professional clinical interpretation and emergency response. It should be used only by trained healthcare professionals, emergency care teams, or authorized medical personnel following ACLS/BLS protocols, hospital guidelines, and the user manual.
Key Features
- Four-in-One Emergency Function: Combines defibrillation, monitoring, pacing, and AED functionality in a single emergency care device.
- BTE Waveform Technology: Biphasic Truncated Exponential waveform with impedance compensation supports efficient shock delivery workflow.
- Rapid Charging Performance: Charges to 200J in less than 5 seconds and 360J in less than 8 seconds with a new fully charged battery.
- Wide Energy Selection: Supports selectable energy levels from 1J to 360J for adult, pediatric, and neonatal emergency care needs.
- 7-Inch Color Display: Clear display supports waveform, values, prompts, and monitoring information for clinical interpretation.
- CPR Guidance Mode: Provides visual and audio guidance aligned with current AHA and ERC guideline-based workflow support.
- Advanced Monitoring Support: Supports ECG, SpO2, NIBP, respiration, and temperature monitoring during emergency care.
- Portable Emergency Design: Approx. 5.2 kg lightweight structure with shock-absorbing handle and IP54 protection for ambulance and transport use.
Technical Specifications
| Product Name | i6 Defibrillator Monitor |
| Product Category | Defibrillator Monitor / Emergency Cardiac Care Device |
| Core Functions | Defibrillation, Monitoring, Pacing, AED |
| Power Supply | AC 100-240 V, 50/60 Hz |
| Battery Type | Rechargeable lithium-ion battery pack |
| Waveform | Biphasic Truncated Exponential with impedance compensation |
| Impedance Range | 25 Ω - 200 Ω for external defibrillation |
| Energy Levels | 1, 2, 3, 5, 7, 10, 15, 20, 30, 50, 70, 100, 150, 170, 200, 300, 360 J |
| Charge Time at 200J | Less than 5 seconds with new fully charged battery |
| Charge Time at 360J | Less than 8 seconds with new fully charged battery |
| Defibrillation Modes | Manual asynchronous and synchronous, AED |
| Pacing Modes | Fixed mode and On-Demand mode |
| Pacing Waveform | Monophasic square wave pulse |
| Pacing Rate | 40-170 ppm, ±1.5% |
| Output Current | 0-200 mA, ±5% or ±5 mA |
| ECG | 5-Lead ECG |
| SpO2 | Continuous oxygen saturation monitoring |
| NIBP | Non-invasive blood pressure monitoring |
| Respiration | Respiratory rate monitoring |
| Temperature | T1 and T2 channels |
| Display | 7-inch color display with three wave curves |
| Patient Support | Adult, pediatric, and neonatal patient support |
| Protection Rating | IP54 protection |
| Dimensions | 32.0 × 20.0 × 12.0 cm |
| Weight | Approx. 5.2 kg |
Product Benefits
- Supports faster emergency response during cardiac arrest and shockable rhythm situations.
- Combines defibrillation, AED, pacing, and monitoring functions to reduce dependency on multiple emergency devices.
- Rapid charge performance supports time-sensitive emergency care workflow.
- Manual and AED modes support both advanced clinician control and guided emergency response use.
- Continuous monitoring of ECG, SpO2, NIBP, respiration, and temperature supports patient observation during therapy.
- Portable design with approx. 5.2 kg weight supports emergency transport and ambulance use.
- CPR guidance mode helps support standardized resuscitation workflow for trained users.
- IP54 protection supports use in ambulance, emergency, and out-of-hospital care environments.
Applications
The i6 Defibrillator Monitor is suitable for emergency departments, ICUs, CCUs, cardiac care units, operation theatres, ambulance services, trauma care units, emergency response teams, and critical care transport settings. It can support emergency defibrillation, AED-guided response, cardiac pacing, and vital sign monitoring during urgent patient care.
The device is intended for professional medical use. It should be operated by trained doctors, emergency medical technicians, critical care teams, nurses, or authorized healthcare personnel according to hospital protocol, emergency cardiac life support guidelines, and device instructions.
How It Works
- Continuously monitors patient vital signs in real time when connected with appropriate monitoring sensors.
- Supports immediate defibrillation or pacing readiness during emergency cardiac care situations.
- Biphasic waveform automatically compensates for patient impedance during external defibrillation.
- Manual mode allows trained clinicians to select energy level and control advanced cardiac life support workflow.
- AED mode provides guided instructions for emergency response use according to device prompts.
- Monitoring function supports ECG, SpO2, NIBP, respiration, and temperature observation during therapy.
How to Use
- Power the unit using AC supply or the rechargeable battery pack.
- Check device readiness, battery level, display, cables, paddles or pads, and monitoring sensors before use.
- Attach ECG leads, defibrillation pads or paddles, and required monitoring sensors as per patient condition.
- Select the required mode: AED, Manual Defibrillation, Monitoring, or Pacing.
- For manual defibrillation, select the appropriate energy level and charge the device as per clinical protocol.
- For AED mode, follow the device’s visual and audio prompts step by step.
- Deliver therapy only when clinically indicated and ensure all safety precautions are followed.
- Continue real-time monitoring and document events according to hospital or emergency care protocol.
Why Choose This Defibrillator Monitor?
The i6 Defibrillator Monitor is designed for healthcare facilities and emergency response teams that need a compact cardiac emergency system with defibrillation, AED, pacing, and monitoring functions. Its rapid charge capability, multi-parameter monitoring, CPR guidance, IP54 protection, and lightweight design make it suitable for critical care departments and transport environments.
For hospitals, ICUs, emergency rooms, ambulances, and cardiac response teams, this device supports standardized emergency workflow and helps clinicians manage time-sensitive cardiac events with clear display guidance and monitoring support. Buyers should confirm configuration, compatible consumables, service support, and installation or training requirements before purchase.
FAQs
1. What is the i6 Defibrillator Monitor used for?
The i6 Defibrillator Monitor is used for emergency cardiac care, including manual defibrillation, AED-guided response, pacing, and patient monitoring. It is suitable for hospitals, ICUs, emergency departments, ambulances, and critical care transport settings where rapid cardiac response may be required.
2. Does this device support AED and manual defibrillation?
Yes, the device supports AED mode as well as manual defibrillation modes including asynchronous and synchronous operation. AED mode provides guided prompts, while manual mode allows trained clinicians to select energy and manage advanced cardiac life support workflow.
3. What monitoring parameters are supported?
The monitor supports 5-lead ECG, SpO2, non-invasive blood pressure, respiration rate, and temperature monitoring with T1 and T2 channels. These parameters support patient observation during emergency care, transport, pacing, and defibrillation-related workflow.
4. What is the charge time of this defibrillator?
As per the provided details, the device charges to 200J in less than 5 seconds and 360J in less than 8 seconds with a new fully charged battery. Actual performance may depend on battery condition and operating environment.
5. Who should operate this defibrillator monitor?
This device should be operated by trained healthcare professionals, emergency medical teams, or authorized users familiar with defibrillation, AED use, pacing, CPR guidance, and patient monitoring protocols. Users should follow the device manual and applicable emergency care guidelines.
