The Yuwell YH-830 BiPAP Machine is part of the BreathCare II series. It provides non-invasive positive airway pressure through a mask. The device is designed for patients who need doctor-prescribed breathing support. It offers five therapy modes, a heated humidifier, and a clear colour display.
In bilevel modes, the machine can give one pressure when a person breathes in and a lower pressure when they breathe out. This is different from CPAP, which provides continuous pressure. The right treatment mode and pressure settings depend on a clinical assessment. For home users, the YH-830 offers simple controls; for care teams, it provides a way to review stored therapy information.
The YH-830 offers CPAP, spontaneous (S), timed (T), spontaneous/timed (ST) and VGPS modes. Its overall device pressure range is 4–30 cmH₂O. The CPAP setting range is 4–20 cmH₂O, as listed in the user manual. IPAP, EPAP, backup rate and other applicable settings must follow the prescription and the selected mode.
The colour display and microSD card help care teams view and review available therapy data. Leak compensation and a ramp feature support device operation. Before selecting this machine, clinicians should check the intended use, patient needs, mask compatibility and monitoring requirements. This is the standard YH-830 PAP device, not the separately listed YH-830 hospital trolley model.
| Specification | Details |
|---|---|
| Brand / Series | Yuwell / BreathCare II |
| Model | YH-830 (standard Bi-Level PAP) |
| Therapy Modes | CPAP, S, T, ST, VGPS |
| Overall Pressure Range | 4–30 cmH₂O |
| CPAP Mode Setting Range | 4–20 cmH₂O |
| Pressure Accuracy | ±0.5 cmH₂O |
| Ramp Time | 0–45 minutes |
| Humidifier | Heated humidifier |
| Display & Controls | Colour display, rotary knob |
| Data Storage | microSD card (included) |
| Altitude Compensation | Automatic, up to 3,500 m |
| Electrical Supply | AC 100–240 V, 50–60 Hz; adapter output 24 V DC |
Pressure limits vary by mode. Refer to the supplied user manual for complete settings and precautions.
For patients whose clinician has selected suitable PAP therapy at home.
For appropriate patients who need bilevel support or follow-up review.
For supervised use when the prescription fits the device's intended purpose.
For purchasing teams checking model, modes, mask fit and supply details.
Place the device on a firm, level surface. Connect the prescribed tube and correctly sized, compatible vented mask. Fill the humidifier with distilled water, as directed in the manual. A trained professional should set the therapy mode and pressure before first use.
Empty and clean the water chamber as the manual advises. Check the filter, tubing and mask regularly. Do not use hot water in the humidifier tank. Keep air inlets clear, and do not adjust prescribed treatment pressures on your own.
The manufacturer lists these core items. Confirm the exact mask size, accessories and warranty with MeddeyGo before ordering.
Buying for home care, a sleep clinic or a healthcare facility? Share your required model, quantity and delivery location with MeddeyGo. Our team can help with product details, stock, package contents and procurement support. For therapy selection, please consult your prescribing clinician.
Call MeddeyGo: 8586012345Mon–Sat, 10:30 AM–6:00 PM
It provides prescribed positive airway pressure through a mask. The doctor decides if this device and its modes are suitable for a patient.
CPAP provides continuous pressure. Bilevel PAP can provide one pressure for breathing in and a lower one for breathing out.
Yes. It supports S, T, ST, CPAP and VGPS. Mode selection and settings must follow the prescription.
Yes. The manufacturer lists a heated humidifier with the standard YH-830 set.
Yes. The microSD card stores therapy data. The display and supported software allow review of available information.
No. Use a suitable, correctly sized vented mask that is compatible with this device and approved by your care provider.
No. This listing describes the standard BreathCare II YH-830 device. Confirm a hospital-specific configuration separately if required.
Use the YH-830 only under medical direction and follow the supplied user manual. It is not a substitute for emergency or life-support ventilation. This PAP device is intended for single-patient use. Seek urgent medical care for severe breathlessness, chest pain or other emergency symptoms. Do not change therapy settings without your clinician's advice.
Browse BiPAP machines, compare CPAP devices, or view respiratory masks and tubing. Always check fit and compatibility before buying an accessory.
Your cart is currently empty.
Not sure where to start?
Try these collections:
10000 in stock
The Yuwell YH-830 BiPAP Machine is part of the BreathCare II series. It provides non-invasive positive airway pressure through a mask. The device is designed for patients who need doctor-prescribed breathing support. It offers five therapy modes, a heated humidifier, and a clear colour display.
In bilevel modes, the machine can give one pressure when a person breathes in and a lower pressure when they breathe out. This is different from CPAP, which provides continuous pressure. The right treatment mode and pressure settings depend on a clinical assessment. For home users, the YH-830 offers simple controls; for care teams, it provides a way to review stored therapy information.
The YH-830 offers CPAP, spontaneous (S), timed (T), spontaneous/timed (ST) and VGPS modes. Its overall device pressure range is 4–30 cmH₂O. The CPAP setting range is 4–20 cmH₂O, as listed in the user manual. IPAP, EPAP, backup rate and other applicable settings must follow the prescription and the selected mode.
The colour display and microSD card help care teams view and review available therapy data. Leak compensation and a ramp feature support device operation. Before selecting this machine, clinicians should check the intended use, patient needs, mask compatibility and monitoring requirements. This is the standard YH-830 PAP device, not the separately listed YH-830 hospital trolley model.
| Specification | Details |
|---|---|
| Brand / Series | Yuwell / BreathCare II |
| Model | YH-830 (standard Bi-Level PAP) |
| Therapy Modes | CPAP, S, T, ST, VGPS |
| Overall Pressure Range | 4–30 cmH₂O |
| CPAP Mode Setting Range | 4–20 cmH₂O |
| Pressure Accuracy | ±0.5 cmH₂O |
| Ramp Time | 0–45 minutes |
| Humidifier | Heated humidifier |
| Display & Controls | Colour display, rotary knob |
| Data Storage | microSD card (included) |
| Altitude Compensation | Automatic, up to 3,500 m |
| Electrical Supply | AC 100–240 V, 50–60 Hz; adapter output 24 V DC |
Pressure limits vary by mode. Refer to the supplied user manual for complete settings and precautions.
For patients whose clinician has selected suitable PAP therapy at home.
For appropriate patients who need bilevel support or follow-up review.
For supervised use when the prescription fits the device's intended purpose.
For purchasing teams checking model, modes, mask fit and supply details.
Place the device on a firm, level surface. Connect the prescribed tube and correctly sized, compatible vented mask. Fill the humidifier with distilled water, as directed in the manual. A trained professional should set the therapy mode and pressure before first use.
Empty and clean the water chamber as the manual advises. Check the filter, tubing and mask regularly. Do not use hot water in the humidifier tank. Keep air inlets clear, and do not adjust prescribed treatment pressures on your own.
The manufacturer lists these core items. Confirm the exact mask size, accessories and warranty with MeddeyGo before ordering.
Buying for home care, a sleep clinic or a healthcare facility? Share your required model, quantity and delivery location with MeddeyGo. Our team can help with product details, stock, package contents and procurement support. For therapy selection, please consult your prescribing clinician.
Call MeddeyGo: 8586012345Mon–Sat, 10:30 AM–6:00 PM
It provides prescribed positive airway pressure through a mask. The doctor decides if this device and its modes are suitable for a patient.
CPAP provides continuous pressure. Bilevel PAP can provide one pressure for breathing in and a lower one for breathing out.
Yes. It supports S, T, ST, CPAP and VGPS. Mode selection and settings must follow the prescription.
Yes. The manufacturer lists a heated humidifier with the standard YH-830 set.
Yes. The microSD card stores therapy data. The display and supported software allow review of available information.
No. Use a suitable, correctly sized vented mask that is compatible with this device and approved by your care provider.
No. This listing describes the standard BreathCare II YH-830 device. Confirm a hospital-specific configuration separately if required.
Use the YH-830 only under medical direction and follow the supplied user manual. It is not a substitute for emergency or life-support ventilation. This PAP device is intended for single-patient use. Seek urgent medical care for severe breathlessness, chest pain or other emergency symptoms. Do not change therapy settings without your clinician's advice.
Browse BiPAP machines, compare CPAP devices, or view respiratory masks and tubing. Always check fit and compatibility before buying an accessory.